Bangalore
08043694881
+919342139468

Products

6814772a5d263414004dd4a4 Card 2

product image
17 Kva Gas Generator Set

Engine Manufacturer Generac Engine Model G FORCE-1000 Net Engine Power 18.7 kWm Engine Cooling System Air Cooled No. of Cylinder and Position 2, Vee Displacement 999 cc Aspiration Naturally Aspirated Bore x Stroke 90 x 78.58 mm Recommended Fuel LPG Combustion system Electronic spark Injection Compression Ratio 9.5: 1 Total lubricating capacity 1.8 Liters Total coolant capacity NA Fuel Consumption  Full Load (Prime) 3.91 kg/hr  75% Load 3.15 kg/hr  50% Load 2.45 kg/hr

6814772a5d263414004dd4a4 Card 2

product image
1010 Kva Gas Generator Set

PRP - Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power. LTP - Limited-Time running Power: It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 h of operation per year (whose no more than 300 for continuative use) with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. No overload capability is available.

6814772a5d263414004dd4a4 Card 2

product image
750 Kva Gas Generator set

PRP - Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power. LTP - Limited-Time running Power: It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 h of operation per year (whose no more than 300 for continuative use) with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. No overload capability is available.

6814772a5d263414004dd4a4 Card 2

product image
CNG-PNG Generator

Ambient reference conditions 1bar, 25°C, 30% relative humidity ISO-8528 • Power according to ISO-3046 • Maximum unbalance Load across phase shall be 25% • Information based on standard specification equipment unless otherwise stated • Conformance Standards ISO-1460, ISO-8528, ISO-3046 & ISO-13018 • Power availability will vary based on Methane composition of the supplied Gas (minimum 85% methane is recommended). • Oil consumption data is based on oil having Specific gravity of 0.89 • Above specifications are subjected to change without notice due to continuous technical developments.

6814772a5d263414004dd4a4 Card 2

product image
mtu Series 4000

No matter how specific your energy supply requirements, our solutions always give you excellence that is fine-tuned to your exact needs. The mtu Series 4000 diesel generator sets have been doing just that for over 25 years already – for data centers, hospitals, airports, industrial plants, residential buildings, public facilities, decentralized power stations, microgrids, hybrid solutions and numerous other applications around the world. Available in six different power ratings, including standby, prime and continuous power, the mtu Series 4000 diesel gensets cover the range from 1,600 to 4,000 kVA (50 Hz) and from 1,125 to 3,250 kWe (60 Hz). In addition to meeting highest quality, performance and fuel efficiency demands, they continue to define the benchmark for excellence with a variety of highly flexible, eco- and cost-efficient features, including low- and medium-voltage alternators, various controller configurations and mechanical or electrical radiators.

6814772a5d263414004dd4a4 Card 2

product image
Generators

Fuel Efficient Best in class Aesthetics Compact in Size Control Panel Mounted inside the Canopy Built in Residential Silencer Integrated fuel tank Highest Block Loading Capacity Nine stage powder paint finish for canopy Single Window Product Support Designed to work in Extreme enviorment

6814772a5d263414004dd4a4 Card 2

product image
Generators

Radiator, Engine & Alternator mounted on single skid  Radiator with 45°C ambient temperature  Dry type air filter with restriction indicator  Integrated Fuel tank with 09 hours capacity  Fuel Cooler & Fuel pre filter with water Separator  AC Panel and DC Control Panel mounted inside enclosure

6814772a5d263414004dd4a4 Card 2

product image
Generators

Global product design, single factory manufacturing product for the world  Best in class smallest foot print  Services of the future: o Service call request available on your finger tip o Genset health monitoring through mobile App and remote desktop o Remote diagnostic  2 Years or 5000 Hours warranty on entire Diesel Generator System

6814772a5d263414004dd4a4 Card 2

product image
Generators

Radiator, Engine & Alternator mounted on single skid  Radiator with 45°C ambient temperature  Dry type air filter with restriction indicator  Integrated Fuel tank with 09 hours capacity  Fuel Cooler & Fuel pre filter with water Separator  AC Panel and DC Control Panel mounted inside enclosure

6814772a5d263414004dd4a4 Card 2

product image
Generators

Fully authority CRDI engine with superior fuel economy and Industry leading average load factor  Silencer Placement inside enclosure  Digital Voltage & Frequency regulation  Remote monitoring & diagnosis  Major Service points on one side of the system  Longer maintenance interval 500 Hours or 2 Years  No schedule overhaul

Subcategory Tags

Phone Number

08043694881

Please keep 0 before dialling the number.

Email Address tpsgenset@gmail.com

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Address 43/1, 19th Main Road, 11th Cross, Avalahalli

Bangalore, India, 560026